2 Parameters
2.2 List of parameters
SINAMICS G130/G150
372 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the effective P gain of the speed controller.
Dependency: For p0528 = 1, the speed controller gain is represented without any dimensions. In this case, connector output signal
r1468 is increased by a factor of 100 in order to improve the resolution.
Description: Displays the effective integral time of the speed controller.
Description: Sets the P gain for encoderless operation for the speed controller.
Dependency: For p0528 = 1, the speed controller gain is represented without any dimensions.
Note: The product p0341 x p0342 is taken into account when automatically calculating the speed controller (p0340 = 1, 3,
4).
Description: Set the integral time for encoderless operation for the speed controller.
Note: The integral component is stopped if the complete controller output or the sum of controller output and torque pre-
control reach the torque limit.
Description: Sets the signal source for the torque setting value when starting up with motor holding brake.
r1468 CO: Speed controller P-gain effective / n_ctr Kp eff
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6040
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- - -
r1469 Speed controller integral time effective / n_ctr Tn eff
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 5040, 5042,
6040
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
p1470[0...n] Speed controller encoderless operation P-gain / n_ctrl SL Kp
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6040, 6050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.000 999999.000 0.300
p1472[0...n] Speed controller encoderless operation integral time / n_ctrl SL Tn
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6040, 6050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.0 [ms] 100000.0 [ms] 20.0 [ms]
p1475[0...n] CI: Speed controller torque setting value for motor holding brake / n_ctrl M_sv MHB
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6040
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: p2003 Expert list: 1
Min Max Factory setting
- - 0