EasyManua.ls Logo

Siemens SINAMICS G150 - CO: Par_Circuit Phase Voltage Actual Value Phase W; Par_Circuit Gating Unit Status Word 1; Gating Unit ZSW1; Par_Circuit Power Unit Rated Power; PU P_Rated

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
714 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the actual voltage, phase W.
The average value of all power units is displayed in r0089[2].
Description: Displays status word 1 of the power unit.
Description: Displays the rated power of the individual power units connected in parallel for various load duty cycles.
The sum of the rated powers of all power units connected in parallel is displayed in r0206.
Index: [0] = Rated value
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 cont duty cyc
[4] = S6 load duty cycle
Dependency: The value is displayed in [kW] or [hp].
Refer to: p0100, p0205
r7233[0...n] CO: Par_circuit phase voltage actual value phase W / U_phase W act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7240[0...n] Par_circuit gating unit status word 1 / Gating unit ZSW1
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fault time-critical ON OFF -
01 Gating unit mode bit 0 ON OFF -
02 Pulse enable ON OFF -
03 Upper shutdown path Inactive Active -
04 Lower shutdown path Inactive Active -
05 Gating unit mode bit 1 ON OFF -
06 Gating unit mode bit 2 ON OFF -
07 Brake state ON OFF -
08 Brake diagnostics ON OFF -
09 Armature short-circuit braking Active Not active -
10 Gating unit state bit 0 ON OFF -
11 Gating unit state bit 1 ON OFF -
12 Gating unit state bit 2 ON OFF -
13 Alarm status bit 0 ON OFF -
14 Alarm status bit 1 ON OFF -
15 Diagnostics 24 V ON OFF -
r7250[0...4] Par_circuit power unit rated power / PU P_rated
B_INF (Parallel),
VECTOR_G (Parallel)
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Converter Units group: 14_6 Unit selection: p0100
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [kW] - [kW] - [kW]

Table of Contents

Other manuals for Siemens SINAMICS G150

Related product manuals