SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
705
2 Parameters
2.2 List of parameters
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase U (p1828).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a
parallel circuit configuration.
Dependency: Refer to: p1828
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase V (p1829).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a
parallel circuit configuration.
Dependency: Refer to: p1829
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase W (p1830).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a
parallel circuit configuration.
Dependency: Refer to: p1830
Description: Displays the circulating current of phase U as peak value.
p7040[0...n] Par_circuit correction valve lockout time phase U / Comp t_lockout U
VECTOR_G (Parallel) Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [µs] 1000000.00 [µs] 0.00 [µs]
p7042[0...n] Par_circuit correction valve lockout time phase V / Comp t_lockout V
VECTOR_G (Parallel) Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [µs] 1000000.00 [µs] 0.00 [µs]
p7044[0...n] Par_circuit correction valve lockout time phase W / Comp t_lockout W
VECTOR_G (Parallel) Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [µs] 1000000.00 [µs] 0.00 [µs]
r7050[0...n] Par_circuit circulating current phase U / Circ_I_phase U
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]