2 Parameters
2.2 List of parameters
SINAMICS G130/G150
720 List Manual (LH2), 04/2014, A5E03263479A
Description: Sets the number of parameters for the OEM exception list (p7764[0...n]).
p7764[0...n], with n = p7763 - 1
Dependency: Refer to: p7764
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency: The number of indices depends on p7763.
Refer to: p7763
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency: The number of indices depends on p7763.
Refer to: p7763
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: Configuration settings for know-how protection.
p7763 KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
All objects Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 500 1
p7764[0...n] KHP OEM exception list / KHP OEM excep list
B_INF, ENC, HUB,
TB30, TM150, TM31,
TM54F_MA,
TM54F_SL,
VECTOR_G
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: p7763 Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 0
p7764[0...n] KHP OEM exception list / KHP OEM excep list
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: p7763 Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 [0] 7766
[1...499] 0
p7765 KHP configuration / KHP config
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 bin