SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
243
2 Parameters
2.2 List of parameters
Description: Displays the actual output voltage for the test sockets.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Refer to: p0771, r0772, p0776, p0777, p0778, p0779, p0780, p0783, p0784, r0786
Description: Sets the mode for the test sockets.
Value: 96: Physical address (32-bit integer signal unsigned)
97: Physical address (32-bit integer signal)
98: Physical address (32-bit floating-point signal)
99: BICO signal
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Refer to: p0771, r0772, r0774, p0777, p0778, p0779, p0780, p0783, p0784, r0786, p0788, p0789, r0790
Description: The scaling characteristic for the test sockets is defined using two points.
This parameter specifies the x coordinate (percentage) of the first point on the characteristic.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Can only be set when p0776 = 99.
Refer to: p0778, p0779, p0780, r0786
Note: The value 0.00 % corresponds to 2.49 V.
r0774[0...2] Test sockets output voltage / TestSkts U_output
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
p0776[0...2] Test socket mode / Test skt mode
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: 8134
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
96 99 99
p0777[0...2] Test socket characteristic value x1 / Test skt char x1
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8134
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-100000.00 [%] 100000.00 [%] 0.00 [%]