2 Parameters
2.2 List of parameters
SINAMICS G130/G150
684 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the total length of the GUIDs of the OA applications installed on this drive object.
Dependency: Refer to: r4950, r4951, r4955, p4956, r4957, r4958, r4959, r4960
Note: The GUID of an OA application comprises 16 characters plus 1 character major information plus 1 character, minor
information.
GUID: Globally Unique IDentifier
Description: Displays the identifier of the OA applications installed on this drive object.
r4955[0...8]: Identifier of OA application 1
r4955[9...17]: Identifier of OA applications 2, ...
Dependency: Refer to: r4950, r4951, r4952, p4956, r4957, r4958, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
Description: Setting to activate the OA applications installed on this drive object.
r4956[0]: Activates OA application 1
r4956[1]: Activates OA application 2, ...
Value: 0: OA application inactive
1: OA application active
Dependency: Refer to: r4950, r4951, r4952, r4955, r4957, r4958, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
Description: Displays the version of the OA applications installed on this drive object.
r4957[0]: Version of OA application 1
r4957[1]: Version of OA application 2, ...
Dependency: Refer to: r4950, r4951, r4952, r4955, p4956, r4958, r4959, r4960
r4952 OA DO-specific GUID total length / OA DO GUID length
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 288 -
r4955[0...n] OA DO-specific identifier / OA DO ident
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4951 Func. diagram: -
P-Group: OEM range Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p4956[0...n] OA DO-specific activation / OA DO act
All objects Can be changed: C1, T Calculated: - Access level: 4
Data type: Integer16 Dyn. index: r4950 Func. diagram: -
P-Group: OEM range Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
r4957[0...n] OA DO-specific version / OA DO version
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4950 Func. diagram: -
P-Group: OEM range Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 -