SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
649
2 Parameters
2.2 List of parameters
Description: Sets the ratio for the LVDT sensor.
Description: Sets the phase for the LVDT sensor.
Description: Sets the permissible tolerance in encoder pulses for the zero mark distance in the context of zero mark monitoring.
Causes fault F3x100 to appear less frequently.
Description: Sets the positive tolerance window in encoder pulses for limit 1 for the zero mark monitoring.
If the deviation is less than this limit, then the pulse number is not corrected. If it is higher than this limit, fault F3x131
is triggered.
If fault F3x131 is re-parameterized to alarm (A) or no message (N), the encoder pulses which have not been
corrected are added to the accumulator (p4688). The accumulator can be de-activated using p0437.7.
Dependency: Refer to: p0437, p4688
Note: This monitoring is activated by setting p0437.2 = 1 (position actual value correction).
The positive limit describes additional pulses due to EMC.
Description: Sets the negative tolerance window in encoder pulses for limit 1 for the zero mark monitoring.
p4678[0...n] Analog sensor LVDT ratio / An_sens LVDT ratio
ENC, VECTOR_G Can be changed: C2(4) Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [%] 200.00 [%] 50.00 [%]
p4679[0...n] Analog sensor LVDT phase / An_sens LVDT ph
ENC, VECTOR_G Can be changed: C2(4), T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-360.00 [°] 360.00 [°] 0.00 [°]
p4680[0...n] Zero mark monitoring tolerance permissible / ZM_monit tol perm
ENC, VECTOR_G Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1000 4
p4681[0...n] Zero mark monitoring tolerance window limit 1 positive / ZM tol lim 1 pos
ENC, VECTOR_G Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1000 2
p4682[0...n] Zero mark monitoring tolerance window limit 1 negative / ZM tol lim 1 neg
ENC, VECTOR_G Can be changed: C2(4) Calculated: - Access level: 3
Data type: Integer32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1001 0 -1001