2 Parameters
2.2 List of parameters
SINAMICS G130/G150
712 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the measured actual value of phase U as peak value.
The summed value of all power units is displayed in r0069[0].
Description: Displays the measured actual value of phase V as peak value.
The summed value of all power units is displayed in r0069[1].
Description: Displays the measured actual value of phase W as peak value.
The summed value of all power units is displayed in r0069[2].
Description: Displays the measured offset of phase U as peak value.
The summed value of all power units is displayed in r0069[3].
Description: Displays the measured offset of phase V as peak value.
The summed value of all power units is displayed in r0069[4].
r7223[0...n] CO: Par_circuit phase current actual value phase U / I_phase U act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7224[0...n] CO: Par_circuit phase current actual value phase V / I_phase V act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7225[0...n] CO: Par_circuit phase current actual value phase W / I_phase W act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7226[0...n] CO: Par_circuit phase current actual value phase U offset / I_phase U offset
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7227[0...n] CO: Par_circuit phase current actual value phase V offset / I_phase V offset
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]