2 Parameters
2.2 List of parameters
SINAMICS G130/G150
614 List Manual (LH2), 04/2014, A5E03263479A
Description: Sets the signal source for enabling the analog inputs of the Terminal Board 30 (TB30).
Index: [0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Description: Sets the signal source for the enable signal of the analog inputs of Terminal Module 31 (TM31).
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description: Sets the signal source for the analog outputs of the Terminal Board 30 (TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Note: AO: Analog Output
Description: Sets the signal source for the analog outputs of Terminal Module 31 (TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Note: AO: Analog Output
p4069[0...1] BI: TB30 analog inputs signal source for enable / TB30 AI enable
TB30 Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9104
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p4069[0...1] BI: TM31 analog inputs signal source for enable / TM31 AI enable
TM31 Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 9566, 9568
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p4071[0...1] CI: TB30 analog outputs signal source / TB30 AO s s
TB30 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 9099, 9106
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p4071[0...1] CI: TM31 analog outputs signal source / TM31 AO s s
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 9549, 9572
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0