EasyManua.ls Logo

Siemens SINAMICS G150 - BI;CI of BICO Interconnections to Other Drives; BI;CI to Drive; BO;CO of BICO Interconnections to Other Drives; BO;CO to Drive; Reset BICO Interconnections to Other Drives; Reset BICO to Drv

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
867
2 Parameters
2.2 List of parameters
Description: Displays the signal receiver list (Binector Input/Connector Input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency: Refer to: r9490, r9492, p9493
Notice: A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note: All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description: Displays the signal source list (Binector Output/Connector Output, BO/CO) for the first interconnections between this
drive and other drives/drive objects.
Dependency: Refer to: r9490, r9491, p9493
Notice: A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note: All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description: Setting to reset the BICO interconnections to other drives.
Each interconnection can be individually reset.
Value: 0: Set connection to 0
1: Set connection to 1 (100 %)
2: Set connection to factory setting
15: Finished
Dependency: Refer to: r9490, r9491, r9492
Note: All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
r9491[0...9] BI/CI of BICO interconnections to other drives / BI/CI to drive
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9492[0...9] BO/CO of BICO interconnections to other drives / BO/CO to drive
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p9493[0...9] Reset BICO interconnections to other drives / Reset BICO to drv
All objects Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 15 15