2 Parameters
2.2 List of parameters
SINAMICS G130/G150
400 List Manual (LH2), 04/2014, A5E03263479A
If the value that is entered exceeds the rated speed, then a change is made to the inner cos phi = 1 over the complete
speed range.
Description: Sets the smoothing time constant for the setpoint of the field-generating current components.
The current filtered in this way is included in the calculation of the cos phi.
Description: Displays the steady-state field generating current setpoint (Id_set).
Note: Re index 1:
Displays the stationary field-generating current on the stator side in the case of separately excited synchronous
motors without the excitation current monitoring component (r1644).
Description: Displays the limited field-generating current setpoint (Id_set).
This value comprises the steady-state field-generating current setpoint r1623 and a dynamic component that is only
set when changes are made to the flux setpoint.
Description: Sets the gain factor to weight the excitation current setpoint.
p1622[0...n] Field-generating current setpoint smoothing time constant / Id_setp T_smth
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.1 [ms] 200.0 [ms] 20.0 [ms]
r1623[0...1] Field-generating current setpoint (steady-state) / Id_set stationary
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6723, 6726,
6727
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: PEM, REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1624 Field-generating current setpoint total / Id_setp total
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6640, 6721,
6723, 6727
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
p1625[0...n] Excitation current setpoint calibration / I_exc_setp cal
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 200.0 [%] 100.0 [%]