SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
675
2 Parameters
2.2 List of parameters
Index: [0] = Milliseconds
[1] = Days
Dependency: Refer to: r2114, r3102, r4719
Notice: The accuracy of the trigger instant depends on the accuracy of the underlying basis time.
For clarification:
The trigger instant is calculated with a µs accuracy. If the underlying basis time is only available with ms accuracy,
then as a result of rounding effects, an inaccuracy of 1 ms can occur.
When referred to r4719, the trigger instant can therefore deviate somewhat.
Note: If the time calculation of the drive can be synchronized with a higher-level control, then this time can be taken from
the actual UTC time (r3102 ). Otherwise, the time is based on the system runtime (r2114).
Description: Displays the instant in time for fulfilling the trigger condition for trace recorder 1.
The time comprises milliseconds (index 0) and days (index 1).
Index: [0] = Milliseconds
[1] = Days
Dependency: Refer to: r2114, r3102, r4719
Notice: The accuracy of the trigger instant depends on the accuracy of the underlying basis time.
For clarification:
The trigger instant is calculated with a µs accuracy. If the underlying basis time is only available with ms accuracy,
then as a result of rounding effects, an inaccuracy of 1 ms can occur.
When referred to r4719, the trigger instant can therefore deviate somewhat.
Note: If the time calculation of the drive can be synchronized with a higher-level control, then this time can be taken from
the actual UTC time (r3102 ). Otherwise, the time is based on the system runtime (r2114).
Description: Displays the free memory for the trace in bytes.
Dependency: Refer to: r4708
Description: The function generator is started with p4800 = 1.
The signal is only generated for a 1 signal of binector input p4819.
Value: 0: Stop function generator
1: Start function generator
2: Check function generator parameterization
3: Start function generator without enable signals
Dependency: Refer to: p4819
r4798[0...1] Trace 1 trigger instant / Trace 1 t_trigger
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4799 Trace memory location free / Trace mem free
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
p4800 Function generator control / FG control
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 3 0