SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
821
2 Parameters
2.2 List of parameters
Note: The interface configuration (p8900 and following) is activated with p8905.
The active DHCP mode is displayed in parameter r8914.
The parameter is not influenced by setting the factory setting.
If value = 0:
DHCP deactivated.
If value = 1:
Reserved.
If value = 2:
DHCP activated. The MAC address of this interface is used for client identification.
If value = 3:
DHCP activated. The station name of this interface is used for client identification.
Description: Setting to activate the interface configuration for the Industrial Ethernet interface (X127) on the Control Unit.
p8905 is automatically set to 0 at the end of an operation.
Value: 0: No function
1: Activate configuration
2: Activate and save configuration
3: Delete configuration
Dependency: Refer to: p8900, p8901, p8902, p8903
Note: Re p8905 = 1:
The interface configuration (p8900 and following) is activated.
Re p8905 = 2:
The interface configuration (p8900 and following) is activated and saved to non-volatile memory.
Re p8905 = 3:
The interface configuration is reset to the factory setting at all points.
The factory settings for the interface configuration are loaded on activation (p8905 = 1) or at the next POWER ON.
Description: Activation of the FTP server.
Permits the FTP access to the /INSTALL/SINAMICS directory of the memory card.
Value: 0: No
1: Yes
Note: Activation of the FTP server becomes effective immediately.
Deactivation only becomes effective after POWER ON of the Control Unit.
Before commissioning the system for the first time, the FTP server is activated independent of the parameter setting.
p8905 IE Interface configuration / IE IF config
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0
p8908 Activate FTP / Act FTP
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0