EasyManua.ls Logo

Siemens SINAMICS G150 - Parameters for Power Unit Data Sets (PDS)

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
1017
2 Parameters
2.3 Parameters for data sets
2.3.5 Parameters for power unit data sets (PDS)
The following list contains the parameters that are dependent on the power unit data sets.
Product: SINAMICS G130/G150, Version: 4702900, Language: eng, Type: PDS
p0121[0...n] Power unit component number / PU comp_no
p0124[0...n] Power unit detection via LED / PU detection LED
p0125[0...n] Activate/de-activate power unit components / PU_comp act/deact
r0126[0...n] Power unit components active/inactive / PU comp act/inact
r0127[0...n] Power unit EEPROM data version / PU EEPROM version
r0128[0...n] Power unit firmware version / PU FW version
r0200[0...n] Power unit code number actual / PU code no. act
p0201[0...n] Power unit code number / PU code no
r0203[0...n] Actual power unit type / PU actual type
r0204[0...n] Power unit hardware properties / PU HW property
p0251[0...n] Operating hours counter power unit fan / PU fan t_oper
p0254[0...n] Operating hours counter power unit fan inside the converter / PU inner fan t_op
p0895[0...n] BI: Activate/de-activate power unit components / PU_comp act/deact
p3901[0...n] Power unit EEPROM Vdc offset calibration / PU EEPROM Vdc offs
p7001[0...n] Par_circuit power units enable / PU enable
r7002[0...n] CO: Par_circuit status power units / Status PU
r7020[0...n] CO: Par_circuit deviation current in phase U / Phase U curr dev
r7021[0...n] CO: Par_circuit deviation current in phase V / Phase V curr dev
r7022[0...n] CO: Par_circuit deviation current in phase W / Phase W curr dev
r7030[0...n] CO: Par_circuit DC link voltage deviation / Vdc deviation
p7040[0...n] Par_circuit correction valve lockout time phase U / Comp t_lockout U
p7042[0...n] Par_circuit correction valve lockout time phase V / Comp t_lockout V
p7044[0...n] Par_circuit correction valve lockout time phase W / Comp t_lockout W
r7050[0...n] Par_circuit circulating current phase U / Circ_I_phase U
r7051[0...n] Par_circuit circulating current phase V / Circ_I_phase V
r7052[0...n] Par_circuit circulating current phase W / Circ_I_phase W
r7200[0...n] Par_circuit power unit overload I2t / PU overload I2t
r7201[0...n] CO: Par_circuit power unit temperatures max. inverter / PU temp max inv
r7202[0...n] Par_circuit power unit temperatures max. depletion layer / PU TempMaxDepLayer
r7203[0...n] CO: Par_circuit power unit temperatures max. rectifier / PU temp max rect
r7204[0...n] CO: Par_circuit power unit temperatures air intake / PU temp air intake
r7205[0...n] Par_circuit power unit temperatures electronics / PU temp electr
r7206[0...n] Par_circuit power unit temperatures inverter 1 / PU temp inv 1
r7207[0...n] Par_circuit power unit temperatures inverter 2 / PU temp inv 2
r7208[0...n] Par_circuit power unit temperatures inverter 3 / PU temp inv 3
r7209[0...n] Par_circuit power unit temperatures inverter 4 / PU temp inv 4
r7210[0...n] Par_circuit power unit temperatures inverter 5 / PU temp inv 5
r7211[0...n] Par_circuit power unit temperatures inverter 6 / PU temp inv 6
r7212[0...n] Par_circuit power unit temperatures inverter 1 / PU temp rect 1
r7213[0...n] Par_circuit power unit temperatures inverter 2 / PU temp rect 2
r7214[0...n] Par_circuit power unit temperatures depletion layer 1 / PU temp DepLayer 1
r7215[0...n] Par_circuit power unit temperatures depletion layer 2 / PU temp DepLayer 2
r7216[0...n] Par_circuit power unit temperatures depletion layer 3 / PU temp DepLayer 3
r7217[0...n] Par_circuit power unit temperatures depletion layer 4 / PU temp DepLayer 4
r7218[0...n] Par_circuit power unit temperatures depletion layer 5 / PU temp DepLayer 5
r7219[0...n] Par_circuit power unit temperatures depletion layer 6 / PU temp DepLayer 6
r7220[0...n] CO: Par_circuit drive output current maximum / Drv I_outp max
r7222[0...n] CO: Par_circuit absolute current actual value / I_act abs val
r7223[0...n] CO: Par_circuit phase current actual value phase U / I_phase U act val
r7224[0...n] CO: Par_circuit phase current actual value phase V / I_phase V act val
r7225[0...n] CO: Par_circuit phase current actual value phase W / I_phase W act val