2 Parameters
2.2 List of parameters
The significance of the assignment parameters is as follows:
p517[0] BiCo number assigned p514[2] (reference quantity 03)
..
p517[19] BiCo number assigned p514[2] (reference quantity 03)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p518[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p518[0] BiCo number assigned p514[3] (reference quantity 04)
..
p518[19] BiCo number assigned p514[3] (reference quantity 04)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p519[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p519[0] BiCo number assigned p514[4] (reference quantity 05)
..
p519[19] BiCo number assigned p514[4] (reference quantity 05)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p520[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
p0518[0...19] Assignment parameter 4 in reference to p514[3] / BiCoList4_ref4
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0519[0...19] Assignment parameter 5 in reference to p514[4] / BiCoList5_ref5
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0520[0...19] Assignment parameter 6 in reference to p514[5] / BiCoList6_ref6
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0