p514[9]reference quantity 10
Up to 20 BiCos can be scaled to each of these 10 reference quantities.
Assignment parameters p515[0..19] up to p524[0..19] have been introduced for this purpose.
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p515[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p515[0] BiCo number assigned p514[0] (reference quantity 01)
..
p515[19] BiCo number assigned p514[0] (reference quantity 01)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p516[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p516[0] BiCo number assigned p514[1] (reference quantity 02)
..
p516[19] BiCo number assigned p514[1] (reference quantity 02)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p517[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
p0515[0...19] Assignment parameter 1 in reference to p514[0] / BiCoList1_ref1
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0516[0...19] Assignment parameter 2 in reference to p514[1] / BiCoList2_ref2
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0517[0...19] Assignment parameter 3 in reference to p514[2] / BiCoList3_ref3
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0