SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
171
2 Parameters
2.2 List of parameters
Description: Sets the number of filler bits for double absolute value transfer in the SSI protocol.
Dependency: Refer to: p0429
Notice: This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note: This parameter is only of significance for p0429.2 = 1.
Description: Displays the relationship between the electrical and mechanical pole positions.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note: A value of zero is displayed if an encoder is not present.
Description: Displays the effective filter time for a squarewave encoder.
The filter time is set using p0438.
Dependency: Refer to: p0438
Note: A value of zero is displayed if an encoder is not present.
Description: Displays the effective filter time for a squarewave encoder.
The filter time is set using p0438.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p0438
Note: A value of zero is displayed if an encoder is not present.
p0449[0...n] Encoder SSI number of bits filler bits / Enc SSI fill bits
ENC, VECTOR_G Can be changed: C2(4) Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 1
r0451[0...2] Commutation angle factor / Enc commut_factor
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: 4710
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0452 Squarewave encoder filter time display / Enc t_filt displ
ENC Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [µs] - [µs] - [µs]
r0452[0...2] Squarewave encoder filter time display / Enc t_filt displ
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [µs] - [µs] - [µs]