SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
397
2 Parameters
2.2 List of parameters
Description: Sets the excitation amplitude (voltage-time pulse) for the pulse technique for estimating the continuous rotor position.
Dependency: Refer to: p1605, p1750
Description: Displays the signal responses to the excitation of the pulse technique.
Index: [0] = Phase R
[1] = Phase S
[2] = D estimated
[3] = Q estimated
[4] = D estimated AC
[5] = Q estimated AC
[6] = Pointer length AC
Dependency: Refer to: p1605, p1607, p1750
Description: Sets the stator current setpoint for operation of a separately-excited synchronous motor (FEM) in operating mode I/f
(p1300 = 18).
Description: Sets the static torque setpoint for sensorless vector control.
This parameter is entered as a percentage referred to the rated motor torque (r0333).
For sensorless vector control, when the motor model is shut down, an absolute current is impressed. p1610
represents the maximum load that occurs at a constant setpoint speed.
Notice: p1610 should always be set to at least 10 % higher than the maximum steady-state load that can occur.
Note: For p1610 = 0%, a current setpoint is calculated that corresponds to the no-load case (ASM: rated magnetizing
current).
For p1610 = 100 %, a current setpoint is calculated that corresponds to the rated motor torque.
p1607[0...n] Pulse technique stimulus / Puls stimulus
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0.000 [mVs] 20000.000 [mVs] 32.000 [mVs]
r1608[0...6] CO: Pulse technique response / Puls response
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: ASM, REL, FEM Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
p1609[0...n] I/f operation current setpoint / I/f op I_setp
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]
p1610[0...n] Torque setpoint static (sensorless) / M_set static
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6700, 6721,
6722, 6726
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-200.0 [%] 200.0 [%] 50.0 [%]