2 Parameters
2.2 List of parameters
SINAMICS G130/G150
544 List Manual (LH2), 04/2014, A5E03263479A
Description: Sets the signal source for the selection of the "Switch-in motor" function.
When the function is selected, monitoring of the switches is de-activated with the "bypass" function. This means that
the power unit can be connected to other motors via an external control without switch monitoring responding.
Description: Sets the reference point offset for search for reference.
Description: Display and connector output of the actual reference quantity for the frequency (p2000).
All frequencies specified as relative value are referred to this reference quantity. The reference quantity corresponds
to 100% or 4000 hex (word) or 4000 0000 hex (double word).
This parameter has the unit Hz.
Dependency: Refer to: p2000
Note: This BICO parameter provides the numerical value of the reference quantity p2000 as a connector output for
interconnection with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connector
output in DCC. This BICO parameter is not suitable for interconnecting for cyclic communication.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Technology controller de-activated Yes No -
01 Technology controller limited Yes No -
02 Technology controller motorized
potentiometer limited max
Yes No -
03 Technology controller motorized
potentiometer limited min
Yes No -
08 Technology controller actual value at the
minimum
Yes No -
09 Technology controller actual value at the
maximum
Yes No -
10 Technology controller output at the
minimum
Yes No -
11 Technology controller output at the
maximum
Yes No -
p2369 BI: Closed-loop cascade control, control word / Csc_ctrl STW
VECTOR_G
(Tech_ctrl)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p2600 EPOS search for reference reference point offset / Ref_pt offset
B_INF Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dyn. index: - Func. diagram: 3612
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-2147482648 [LU] 2147482647 [LU] 0 [LU]
r2700 CO: Reference frequency / f_ref
B_INF Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -