2 Parameters
2.2 List of parameters
SINAMICS G130/G150
820 List Manual (LH2), 04/2014, A5E03263479A
Dependency: Refer to: p8905, r8910
Note: An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
The interface configuration (p8900 and following) is activated with p8905 = 1.
The parameter is not influenced by setting the factory setting.
IE: Industrial Ethernet
Description: Sets the IP address for the Industrial Ethernet interface (X127) on the Control Unit.
The active IP address is displayed in r8911.
Dependency: Refer to: p8905, r8911
Note: The interface configuration (p8900 and following) is activated with p8905 = 1.
The parameter is not influenced by setting the factory setting.
Description: Sets the default gateway for the Industrial Ethernet interface (X127) on the Control Unit.
The active default gateway is displayed in r8912.
Dependency: Refer to: p8905, r8912
Note: The interface configuration (p8900 and following) is activated with p8905 = 1.
The parameter is not influenced by setting the factory setting.
Description: Sets the subnet mask for the Industrial Ethernet interface (X127) on the Control Unit.
The active subnet mask is displayed in r8913.
Dependency: Refer to: p8905, r8913
Note: The interface configuration (p8900 and following) is activated with p8905 = 1.
The parameter is not influenced by setting the factory setting.
Description: Sets the DHCP mode for the Industrial Ethernet interface (X127) on the Control Unit.
p8901[0...3] IE IP Address of Station / IE IP of Stat
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8902[0...3] IE Default Gateway of Station / IE Def Gateway
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8903[0...3] IE Subnet Mask of Station / IE Subnet Mask
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8904 IE DHCP mode / IE DHCP mode
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0