2 Parameters
2.2 List of parameters
SINAMICS G130/G150
584 List Manual (LH2), 04/2014, A5E03263479A
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 3rd value pair of the friction characteristic.
Dependency: Refer to: p3822, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 4th value pair of the friction characteristic.
Dependency: Refer to: p3823, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 5th value pair of the friction characteristic.
Dependency: Refer to: p3824, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3825, p3845
p3832[0...n] Friction characteristic value M2 / Friction M2
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3833[0...n] Friction characteristic value M3 / Friction M3
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3834[0...n] Friction characteristic value M4 / Friction M4
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3835[0...n] Friction characteristic value M5 / Friction M5
VECTOR_G (n/M) Can be changed: T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]