SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
447
2 Parameters
2.2 List of parameters
Description: Displays the nominal stator inductance identified for the 2nd point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the nominal stator inductance identified for the 3rd point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the nominal stator inductance identified for the 4th point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the identified dynamic total leakage inductance.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
r1917[0...2] Identified stator inductance 2 / L_stator 2 ident
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1918[0...2] Identified stator inductance 3 / L_stator 3 ident
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1919[0...2] Identified stator inductance 4 / L_stator 4 ident
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1920[0...2] Identified dynamic leakage inductance / L_leak dyn ident
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]