EasyManua.ls Logo

Siemens SINAMICS G150 - Excitation Current Outside the Tolerance Hysteresis; Excitation Current Outside the Tolerance Delay Time; Flux Outside the Tolerance Threshold Value; Flux N Tol Thresh; Flux Outside the Tolerance Hysteresis; Flux N Tol Hyst

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
561
2 Parameters
2.2 List of parameters
Description: Sets the hysteresis for the "excitation current outside tolerance" message for the excitation current monitoring.
Dependency: Refer to: p3201, p3203
Note: The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
Description: Sets the delay time for the "excitation current outside tolerance" message for the excitation current monitoring.
Dependency: Refer to: p3201, p3202
Note: The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
Description: Sets the threshold value for the "flux outside the tolerance" message for the flux monitoring.
If the absolute value of the difference between the flux setpoint and actual value (r0083 - r0084) falls below the
threshold value with hysteresis longer than the selected delay time, then fault F07914 is output.
This fault is withdrawn when the threshold voltage is undershot.
Dependency: Refer to: r0083, r0084, p3205, p3206
Note: The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
The flux monitoring is only active after magnetizing (r0056.4 = 1).
Description: Sets the hysteresis for the "flux outside tolerance" message for the flux monitoring.
Dependency: Refer to: p3204, p3206
Note: The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
The flux monitoring is only active after magnetizing (r0056.4 = 1).
p3202[0...n] Excitation current outside the tolerance hysteresis / I_exc n Tol hyst
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.1 [%] 100.0 [%] 10.0 [%]
p3203[0...n] Excitation current outside the tolerance delay time / I_exc n Tol t_del
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.0 [s] 10.0 [s] 1.0 [s]
p3204[0...n] Flux outside the tolerance threshold value / Flux n tol thresh
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.1 [%] 100.0 [%] 10.0 [%]
p3205[0...n] Flux outside the tolerance hysteresis / Flux n tol hyst
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Messages Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
0.1 [%] 50.0 [%] 10.0 [%]

Table of Contents

Other manuals for Siemens SINAMICS G150

Related product manuals