EasyManua.ls Logo

Siemens SINAMICS G150 - PS File Fault Code Parameter Not Transferred; PS Fault Code; Number of Parameters to be Saved; Qty Par to Save; Reference Value Change Parameter with Unsuccessful Calculation

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
864 List Manual (LH2), 04/2014, A5E03263479A
Note: All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description: Only for internal Siemens service purposes.
Dependency: Refer to: r9406, r9407
Note: All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description: Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency: Refer to: p0971, p0977
Notice: Inherent to the system, the list of the parameters to be backed up is empty after the following actions:
- Download
- Warm restart
- Factory setting
In these cases, a new parameter backup must be initiated, which is then the starting point for the list of modified
parameters.
Note: The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
Description: Displays the parameters for which the re-calculation was unsuccessful after an internal system reference value
change.
r9408[0...19] PS file fault code parameter not transferred / PS fault code
All objects Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9409 Number of parameters to be saved / Qty par to save
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9450[0...29] Reference value change parameter with unsuccessful calculation /
Ref_chg par n poss
B_INF, ENC,
VECTOR_G
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents

Other manuals for Siemens SINAMICS G150

Related product manuals