SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
129
2 Parameters
2.2 List of parameters
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1, 2):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency: If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the rated motor torque.
Dependency: IEC drives (p0100 = 0): unit Nm
NEMA drives (p0100 = 1): unit lbf ft
Note: For induction and reluctance motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
In the case of multi-motor operation r0333 is increased by the factor p0306 compared to the rated torque of an
individual motor.
Description: Displays the torque constant of the synchronous motor used.
Dependency: IEC drives (p0100 = 0): unit Nm / A
NEMA drives (p0100 = 1): unit lbf ft / A
Refer to: p0316
Note: This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 = p0316 is displayed. For p0316 = 0, r0334 is calculated from p0305 and
p0312 or p0305, p0307, and p0311.
Description: Sets the motor cooling system used.
Value: 0: Non-ventilated
1: Forced cooling
2: Liquid cooling
4: Non-ventilated and internal fan
5: Forced cooling and internal fan
6: Liquid cooling and internal fan
128: No fan
r0333[0...n] Rated motor torque / Mot M_rated
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 7_4 Unit selection: p0100
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r0334[0...n] Actual motor-torque constant / Mot kT act
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 28_1 Unit selection: p0100
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
- [Nm/A] - [Nm/A] - [Nm/A]
p0335[0...n] Motor cooling type / Mot cool type
VECTOR_G Can be changed: C2(1, 3), T Calculated: - Access level: 1
Data type: Integer16 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0 128 0