2 Parameters
2.2 List of parameters
SINAMICS G130/G150
396 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the output of the P flux controller for separately-excited synchronous motors (FEM).
Description: Sets the effective current limit within the pulse technique.
Note: The saturation characteristic of the motor defines the available operating range for the pulse technique.
This operating range can be adjusted using the current limit.
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Otherwise, the rated motor current is used as pre-assigned value.
Description: Sets the applied pulse patterns for estimating the continuous rotor position.
Remark:
See p1750 for the activation of the pulse-pattern technique.
Value: 1: pm
2: ppmm
Dependency: Refer to: p1750
Note: When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Description: Displays the currently applied pulse patterns for estimating the continuous rotor position.
Value: 0: None
1: pm
2: ppmm
Dependency: Refer to: p1605, p1750
r1602 CO: P flux controller output / P flux ctrl outp
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6726, 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
p1604[0...n] Pulse technique current limit / Pulse current lim
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0.00 [Arms] 10000.00 [Arms] 0.00 [Arms]
p1605[0...n] Pulse technique pattern configuration / Puls pattrn config
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
1 2 2
r1606 CO: Pulse technique pattern actual / Puls pattern act
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, REL, FEM Scaling: - Expert list: 1
Min Max Factory setting
0 2 -