2 Parameters
2.2 List of parameters
Note: A value of 99 means that no encoder has been assigned to this drive data set (not configured).
Description: Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 2.
The value corresponds to the number of the assigned encoder data set.
Example:
Encoder data set 1 should be assigned to encoder 2 in drive data set 2.
--> p0188[2] = 1
Note: A value of 99 means that no encoder has been assigned to this drive data set (not configured).
Description: Assign a drive data set (= index) the corresponding encoder data set (EDS) for encoder 3.
The value corresponds to the number of the assigned encoder data set.
Note: A value of 99 means that no encoder has been assigned to this drive data set (not configured).
Description: Displays the properties supported by the power unit firmware.
p0188[0...n] Encoder 2 encoder data set number / Enc 2 EDS number
VECTOR_G Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: DDS, p0180 Func. diagram: 4700, 8570
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 99 99
p0189[0...n] Encoder 3 encoder data set number / Enc 3 EDS number
VECTOR_G Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: DDS, p0180 Func. diagram: 4700, 8570
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 99 99
r0192 Power unit firmware properties 1 / PU FW property 1
B_INF, VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Edge modulation possible Yes No -
01 Free telegram can be selected Yes No -
02 Smart mode possible for Active Line Module Yes No -
03 Safety Integrated possible for VECTOR Yes No -
05 Thermal model expanded Yes No -
06 Liquid cooling Yes No -
07 SERVO pulse frequency changeover DDS-
dependent
Yes No -
08 Simulation mode possible Yes No -
09 Internal armature short-circuit possible Yes No -
10 Autonomous internal armature short-circuit
possible
Yes No -
11 Infeed temperature inputs X21.1/2 Yes No -
12 Integral scaled to half the gating unit clock
cycle freq.
Yes No -
13 Filtering thermal power unit current limit
possible
Yes No -
14 DC link compensation possible in power unit Yes No -
15 PT100 temperature evaluation possible Yes No -
16 Gating unit with pulse frequency
wobbulation possible
Yes No -