2 Parameters
2.2 List of parameters
SINAMICS G130/G150
210 List Manual (LH2), 04/2014, A5E03263479A
The significance of the assignment parameters is as follows:
p520[0] BiCo number assigned p514[5] (reference quantity 06)
..
p520[19] BiCo number assigned p514[5] (reference quantity 06)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p521[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p521[0] BiCo number assigned p514[6] (reference quantity 07)
..
p521[19] BiCo number assigned p514[6] (reference quantity 07)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p522[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p522[0] BiCo number assigned p514[7] (reference quantity 08)
..
p522[19] BiCo number assigned p514[7] (reference quantity 08)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p523[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
p0521[0...19] Assignment parameter 7 in reference to p514[6] / BiCoList7_ref7
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0522[0...19] Assignment parameter 8 in reference to p514[7] / BiCoList8_ref8
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0523[0...19] Assignment parameter 9 in reference to p514[8] / BiCoList9_ref9
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0