EasyManua.ls Logo

Siemens SINAMICS G150 - Assignment Parameter 7 in Reference to P514[6]; Bicolist7_Ref7; Assignment Parameter 8 in Reference to P514[7]; Bicolist8_Ref8; Assignment Parameter 9 in Reference to P514[8]; Bicolist9_Ref9

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
210 List Manual (LH2), 04/2014, A5E03263479A
The significance of the assignment parameters is as follows:
p520[0] BiCo number assigned p514[5] (reference quantity 06)
..
p520[19] BiCo number assigned p514[5] (reference quantity 06)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p521[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p521[0] BiCo number assigned p514[6] (reference quantity 07)
..
p521[19] BiCo number assigned p514[6] (reference quantity 07)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p522[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p522[0] BiCo number assigned p514[7] (reference quantity 08)
..
p522[19] BiCo number assigned p514[7] (reference quantity 08)
Dependency: Refer to: p0514
Description: Assignment parameter for user-specific scaling.
By indexing the assignment parameter p523[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
p0521[0...19] Assignment parameter 7 in reference to p514[6] / BiCoList7_ref7
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0522[0...19] Assignment parameter 8 in reference to p514[7] / BiCoList8_ref8
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0
p0523[0...19] Assignment parameter 9 in reference to p514[8] / BiCoList9_ref9
B_INF, VECTOR_G Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0

Table of Contents