EasyManua.ls Logo

Siemens SINAMICS G150 - Signal Sources for ZSW1 in Interface Mode VIK-NAMUR (P2038 = 2)

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
1075
3 Function diagrams
3.5 PROFIdrive
Fig. 3-37 2451 – ZSW1 status word interconnection (p2038 = 2)
- 2451 -
Function diagram
87654321
fp_2451_54_eng.vsd
DO: VECTOR
S120/S150/G130/G150
27.06.13 V04.07.00
PROFIdrive - ZSW1 status word interconnection (p2038 = 2)
Signal sources for ZSW1 in Interface Mode VIK-NAMUR (p2038 = 2)
<1> Used in telegram 20.
<2> The ZSW1 is generated using the binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...p2088[0].15)
<3> The drive object is ready to accept data.
<4> Interconnection is not disabled.
Signal Meaning
ZSW1.0
ZSW1.1
ZSW1.2
ZSW1.3
ZSW1.4
ZSW1.5
ZSW1.6
ZSW1.8
ZSW1.9
ZSW1.11
ZSW1.12
ZSW1.13
ZSW1.14
ZSW1.15
ZSW1.7
ZSW1.10
1 = Ready for operation (DC link loaded, pulses inhibited)
1 = Ready for switching on
1 = Operation enabled (drive follows n_set)
1 = Fault present
1 = No coast down active (OFF2 inactive)
1 = No fast stop active (OFF3 inactive)
1 = Power-on inhibit active
1 = Alarm present
1 = Speed setpoint - actual value deviation within tolerance t_off
1 = Control requested
1 = f or n comparison value reached/exceeded
1 = I, M, or P limit not reached
Reserved
1 = No motor overtemperature alarm
1 = Command Data Set selection CDS bit 0
1 = Motor rotates forwards (n_act  0)
0 = Motor rotates backwards (n_act < 0)
<3>
p2080[2] = r0899.2
p2080[3] = r2139.3
p2080[4] = r0899.4
p2080[5] = r0899.5
p2080[6] = r0899.6
p2080[7] = r2139.7
p2080[8] = r2197.7
p2080[9] = r0899.9
p2080[10] = r2199.1
p2080[11] = r0056.13
-
p2080[13] = r2135.14
p2080[0] = r0899.0
p2080[1] = r0899.1
p2080[14] = r2197.3
Interconnection
parameters
[2503.7]
[2548.7]
[2503.7]
[2503.7]
[2503.7]
[2548.7]
[2534.7]
[2503.7]
[2536.7]
[2522.7]
-
[2548.7]
-
[2503.7]
[2503.7]
[2534.7]
[Function diagram]
Internal status word
[2610]
[8060]
[2610]
[2610]
[2610]
[8065]
[8010]
[2503]
[8010]
[6060]
-
[8016]
-
[2610]
[2610]
[8011]
[Function diagram]
Signal source
<1>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
<2>
Inverted
p2080[15] = r0836.0
PROFIdrive sampling time
<4>

Table of Contents