2 Parameters
2.2 List of parameters
SINAMICS G130/G150
246 List Manual (LH2), 04/2014, A5E03263479A
Description: Sets the physical address to output signals via the test sockets.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Changes only become effective if p0776 does not equal 99.
Refer to: p0789, r0790
Description: Sets the gain of a signal output of a physical address via test sockets.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Changes only become effective if p0776 does not equal 99.
Refer to: p0788
Description: Displays the actual value of a signal determined via a physical address.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Only effective when p0776 = 97 or p0776 = 96.
Refer to: p0788
Description: Sets the simulation mode for digital inputs.
p0788[0...2] Test sockets physical address / Test skt PhyAddr
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 bin 1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
p0789[0...2] Test sockets physical address gain / TestSktPhyAddrGain
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-340.28235E36 340.28235E36 1.00000
r0790[0...2] Test sockets physical address signal value / TestSktsPhyAddrVal
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0795 CU digital inputs simulation mode / CU DI simulation
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: 2020, 2030,
2031, 2100, 2119, 2120, 2130,
2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 0000
0000 0000 0000 bin