2 Parameters
2.2 List of parameters
SINAMICS G130/G150
572 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the input voltage between phases L2 and L3 for the Voltage Sensing Module (VSM).
Dependency: Refer to: p3660
Note: X521.1 or X522.1: Connection of L1
X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
Description: Displays the status of the temperature evaluation of the Voltage Sensing Module (VSM).
This displays whether the temperature actual value has exceeded the fault/alarm threshold.
Dependency: Refer to: p3665, r3666, p3667, p3668
Description: Setting of the temperature sensor for the Voltage Sensing Module (VSM).
The temperature sensor is connected to terminals X520.5 and X520.6 of the VSM.
Value: 0: No sensor
1: PTC
2: KTY84
Note: The pre-assignment of the parameter depends on the device type.
For chassis power units, the temperature monitoring of the line filter is active (p3665 = 2).
Description: Displays the temperature actual value of a KTY84 temperature sensor connected to the Voltage Sensing Module
(VSM).
Prerequisite:
A KTY84 sensor is connected and p3665 is set to 2.
r3662[0...n] CO: VSM input line supply voltage u2 - u3 / VSM inp u2-u3
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: p0150 Func. diagram: -
P-Group: Closed-loop control Units group: 5_3 Unit selection: p0505
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r3664[0...n] CO: VSM temperature evaluation status / VSM temp status
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: p0150 Func. diagram: 9886
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Alarm is present Yes No -
01 Fault is present Yes No -
p3665[0...n] VSM temperature evaluation sensor type / VSM TempSensorType
VECTOR_G Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: p0150 Func. diagram: 9886
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 2 0
r3666[0...n] CO: VSM temperature KTY / VSM temp KTY
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: p0150 Func. diagram: 9886
P-Group: Closed-loop control Units group: 21_1 Unit selection: p0505
Not for motor type: - Scaling: p2006 Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]