SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
665
2 Parameters
2.2 List of parameters
Description: Displays the trace buffer (record buffer) for trace 0 and signal 1.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 2.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 3.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 4.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 5.
Dependency: Refer to: r4740, p4795
r4741[0...16383] Trace 0 trace buffer signal 1 floating point / Trace 0 tr sig 1
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4742[0...16383] Trace 0 trace buffer signal 2 floating point / Trace 0 tr sig 2
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4743[0...16383] Trace 0 trace buffer signal 3 floating point / Trace 0 tr sig 3
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4744[0...16383] Trace 0 trace buffer signal 4 floating point / Trace 0 tr sig 4
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
r4745[0...16383] Trace 0 trace buffer signal 5 floating point / Trace 0 tr sig 5
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -