2 Parameters
2.2 List of parameters
Description: Sets the synchronization source/technique.
Value: 0: PROFIBUS
1: PROFINET
2: PPI
3: PROFINET PTP
Description: Sets the signal source for the PING event to set the UTC time.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Displays the last synchronizing event in the drive system.
3107[0, 1]: synchronizing event after synchronization
r3107[0]: milliseconds
r3107[1]: days
3107[2, 3]: synchronizing event before synchronization
r3107[2]: milliseconds
r3107[3]: days
Description: Displays the absolute value of the last synchronization deviation that was determined.
r3108[0]: Milliseconds
r3108[1]: Days
p3103 RTC synchronization source / RTC sync_source
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0
p3104 BI: RTC real time synchronization PING / RTC PING
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r3107[0...3] RTC synchronizing time / RTC t_sync
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r3108[0...1] RTC last synchronization deviation / RTC sync_dev
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -