2 Parameters
2.2 List of parameters
Description: Sets the standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8943, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8942, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8942, p8943, p8945
Notice: When the DHCP mode is active (p8944 > 0), then PROFINET communication via this interface is no longer possible!
However, the interface can be used by the STARTER/SCOUT commissioning tool.
Note: The active DHCP mode is displayed in parameter r8954.
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
If value = 0:
DHCP deactivated.
If value = 1:
Reserved.
If value = 2:
DHCP activated. The MAC address of this interface is used for client identification.
If value = 3:
DHCP activated. The station name of this interface is used for client identification.
p8942[0...3] CBE2x Default Gateway of Station / CBE2x Def Gateway
CU_G130_DP
(PROFINET CBE20),
CU_G130_PN
(PROFINET CBE20),
CU_G150_DP
(PROFINET CBE20),
CU_G150_PN
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8943[0...3] CBE2x Subnet Mask of Station / CBE2x Subnet Mask
CU_G130_DP
(PROFINET CBE20),
CU_G130_PN
(PROFINET CBE20),
CU_G150_DP
(PROFINET CBE20),
CU_G150_PN
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0
p8944 CBE2x DHCP Mode / CBE2x DHCP Mode
CU_G130_DP
(PROFINET CBE20),
CU_G130_PN
(PROFINET CBE20),
CU_G150_DP
(PROFINET CBE20),
CU_G150_PN
(PROFINET CBE20)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 0