2 Parameters
2.2 List of parameters
SINAMICS G130/G150
384 List Manual (LH2), 04/2014, A5E03263479A
Description: Sets the regenerative power limit.
Dependency: Refer to: p0500, p1530
Note: The power limit is limited to 300% of the rated motor power.
For power units without regenerative feedback into the line supply, the regenerative power limit is pre-set to 30% of
the motoring power limit p1530 and in the ratio rated drive converter power to rated motor power. If a braking resistor
is connected to the DC link, then the power limit can be correspondingly increased.
Description: Displays the maximum torque/force generating current as a result if all current limits.
Description: Displays the maximum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index: [0] = Limited
[1] = Unlimited
Description: Displays the minimum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index: [0] = Limited
[1] = Unlimited
p1531[0...n] Power limit regenerative / P_max gen
VECTOR_G (n/M) Can be changed: U, T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6640
P-Group: Closed-loop control Units group: 14_5 Unit selection: p0505
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
-100000.00 [kW] -0.01 [kW] -0.01 [kW]
r1533 Current limit torque-generating total / Iq_max total
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6640
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1536[0...1] Current limit maximum torque-generating current / Isq_max
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6640, 6710
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1537[0...1] Current limit minimum torque-generating current / Isq_min
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6640, 6710
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]