2 Parameters
2.2 List of parameters
SINAMICS G130/G150
784 List Manual (LH2), 04/2014, A5E03263479A
Note: For p8805 = 0 (factory setting) the following applies:
Parameter p8809 contains the information described below.
Re p8809[0...3]:
Contains the value from r9781[0] "SI change tracking checksum functional".
Re p8809[4...7]:
Contains the value from r9782[0] "SI change tracking time stamp checksum functional".
Re p8809[8...53]:
Reserved.
Description: Project selection for SINAMICS Link.
Value: 16: SINAMICS Link project 16 participants
64: SINAMICS Link project 64 participants
Note: SINAMICS Link requires that the appropriate CBE20 firmware version is selected (p8835 = 3).
The parameter must be set the same for all participants.
A change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
Description: Sets the clock cycle for SINAMICS Link.
Re index 0:
0 = clock synchronous mode not activated, 1 = clock synchronous mode activated
Re index 1:
Possible values: 500, 1000, 2000 µs
Index: [0] = Activate isochronous mode
[1] = Bus CC [µs]
Dependency: Refer to: p8811
Note: SINAMICS Link requires that the appropriate CBE20 firmware version is selected (p8835 = 3).
A change only becomes effective after a POWER ON.
The parameter is not influenced by setting the factory setting.
Re index 0:
Is applicable for the synchronization of the application. The SINAMICS Link itself is always synchronous.
Re index 1:
The value must be set the same for all participants.
When newly selecting the project p8811, p8812[1] is set to the factory setting.
For p8811 = 16, the following applies:
Min/max/factory setting: 500/500/500 µs
For p8811 = 64, the following applies:
Min/max/factory setting: 1000/2000/2000 µs
p8811 SINAMICS Link project selection / SINAMICS Link proj
CU_G130_DP
(PROFINET CBE20),
CU_G130_PN
(PROFINET CBE20),
CU_G150_DP
(PROFINET CBE20),
CU_G150_PN
(PROFINET CBE20)
Can be changed: C1(1) Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: 2198
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
16 64 64
p8812[0...1] SINAMICS Link settings / SINAMICS Link cl c
CU_G130_DP
(PROFINET CBE20),
CU_G130_PN
(PROFINET CBE20),
CU_G150_DP
(PROFINET CBE20),
CU_G150_PN
(PROFINET CBE20)
Can be changed: C1(1) Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: 2198
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 2000 [0] 1
[1] 2000