2 Parameters
2.2 List of parameters
SINAMICS G130/G150
954 List Manual (LH2), 04/2014, A5E03263479A
Description: Only for internal Siemens service purposes.
Description: Only for internal Siemens service purposes.
Description: Excessive components that have not been assigned can be removed from the component target topology using this
parameter.
Index 0:
The values 2 ... 199 are permissible.
Index 1:
= 0: Ready.
= 1: Reset (only indices 0 and 1)
= 2: Reset all (indices 0 and 1 and flagged entries).
= 3: Check and flag for deletion.
Index: [0] = Component number
[1] = Reset or check and flag for deletion
Note: Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
Description: Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
Index 0 = license key character 1 (e.g. 69 dec)
Index 1 = license key character 2 (e.g. 65 dec)
...
p9915 DRIVE-CLiQ data transfer error shutdown threshold master / DQ fault master
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex
p9916 DRIVE-CLiQ data transfer error shutdown threshold slave / DQ fault slave
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: C1(1) Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 0007 07FF hex 0007 02FF hex
p9917[0...1] Delete component / Delete comp
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: C1(30) Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 199 0
p9920[0...99] Licensing enter license key / Enter license key
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -