Siemens SINAMICS G150 - CO: Central Measuring Probe Status Word Display; Cen Meas ZSW Disp; Macro Binector Input (BI); Macro BI

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
235
2 Parameters
2.2 List of parameters
Description: Displays the measuring time for a falling edge at the digital input for the "central measuring probe evaluation"
function.
The measuring time is specified as 16-bit value with a resolution of 0.25 µs.
r0687[0]: Measuring time, falling edge measuring probe 1
r0687[1]: Measuring time, falling edge measuring probe 2
r0687[2]: Measuring time, falling edge measuring probe 3
r0687[3]: Measuring time, falling edge measuring probe 4
r0687[4]: Measuring time, falling edge measuring probe 5
r0687[5]: Measuring time, falling edge measuring probe 6
r0687[6]: Measuring time, falling edge measuring probe 7
r0687[7]: Measuring time, falling edge measuring probe 8
Note: The parameter is only active for the evaluation procedure p0684 = 0, 1.
For p0684 = 16, r0687[0...7] = 0 is displayed.
Description: Displays the status word for the function "central measuring probe evaluation".
Description: Runs the corresponding macro files.
r0687[0...7] CO: Central measuring probe measuring time falling edge / CenMeas t_meas 1/0
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0688 CO: Central measuring probe status word display / Cen meas ZSW disp
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Digital input measuring probe 1 High Low -
01 Digital input measuring probe 2 High Low -
02 Digital input measuring probe 3 High Low -
03 Digital input measuring probe 4 High Low -
04 Digital input measuring probe 5 High Low -
05 Digital input measuring probe 6 High Low -
06 Digital input measuring probe 7 High Low -
07 Digital input measuring probe 8 High Low -
08 Sub-sampling measuring probe 1 High Low -
09 Sub-sampling measuring probe 2 High Low -
10 Sub-sampling measuring probe 3 High Low -
11 Sub-sampling measuring probe 4 High Low -
12 Sub-sampling measuring probe 5 High Low -
13 Sub-sampling measuring probe 6 High Low -
14 Sub-sampling measuring probe 7 High Low -
15 Sub-sampling measuring probe 8 High Low -
p0700[0...n] Macro Binector Input (BI) / Macro BI
B_INF, VECTOR_G Can be changed: C2(1), T Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: CDS, p0170 Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 999999 0