2 Parameters
2.2 List of parameters
SINAMICS G130/G150
454 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the dynamic factor which is actually achieved for the vibration test
Dependency: Refer to: p1959, p1967
Note: This dynamic factor only refers to the control mode of the speed controller set in p1960.
Description: Displays the determined moment of inertia of the drive.
After it has been determined, the value is transferred to p0341, p0342.
Dependency: IEC drives (p0100 = 0): unit kg m^2
NEMA drives (p0100 = 1): unit lb ft^2
Refer to: p0341, p0342, p1959
Description: Displays the vibration frequencies determined by the vibration test.
Index: [0] = Frequency low
[1] = Frequency high
Dependency: Refer to: p1959
Description: Displays the standard deviations of the vibration frequencies determined by the vibration test
Index: [0] = Standard deviation of low frequency
[1] = Standard deviation of high frequency
Dependency: Refer to: p1959
r1968 Speed_ctrl_opt dynamic factor actual / n_opt dyn_fact act
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r1969 Speed_ctrl_opt moment of inertia determined / n_opt M_inert det
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: 25_1 Unit selection: p0100
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [kgm²] - [kgm²] - [kgm²]
r1970[0...1] Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vib det
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r1971[0...1] Speed_ctrl_opt vibration test standard deviation determined / n_opt std_dev det
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]