2 Parameters
2.2 List of parameters
SINAMICS G130/G150
242 List Manual (LH2), 04/2014, A5E03263479A
Note: Inversion using p0748 has been taken into account.
DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital outputs.
Notice: If telegram 39x is set via p0922 in SINAMICS Integrated, the inversion of the output has no effect.
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for the signal to be output at the test sockets.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Can only be set when p0776 = 99.
Refer to: r0772, r0774, p0776, p0777, p0778, p0779, p0780, p0783, p0784, r0786
Description: Displays the actual value of the signal to be output.
Index: [0] = T0
[1] = T1
[2] = T2
Dependency: Refer to: p0771, r0774, p0776, p0777, p0778, p0779, p0780, p0783, p0784, r0786
p0748 CU invert digital outputs / CU DO inv
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 2030, 2031,
2130, 2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X122.9/X121.7) Inverted Not inverted -
09 DI/DO 9 (X122.10/X121.8) Inverted Not inverted -
10 DI/DO 10 (X122.12/X121.10) Inverted Not inverted -
11 DI/DO 11 (X122.13/X121.11) Inverted Not inverted -
12 DI/DO 12 (X132.9/X131.1) Inverted Not inverted -
13 DI/DO 13 (X132.10/X131.2) Inverted Not inverted -
14 DI/DO 14 (X132.12/X131.4) Inverted Not inverted -
15 DI/DO 15 (X132.13/X131.5) Inverted Not inverted -
p0771[0...2] CI: Test sockets signal source / Test skt S_src
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Integer16 Dyn. index: - Func. diagram: 8134
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
r0772[0...2] Test sockets output signal / TestSktsSignalVal
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8134
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]