2 Parameters
2.2 List of parameters
SINAMICS G130/G150
184 List Manual (LH2), 04/2014, A5E03263479A
Index x + 2 = 20 hex (blank) --> separation between the identification number of serial number
Index x + 3 = first character of the serial number
...
Index y with contents = last character of the serial number
Dependency: Refer to: r0460, r0461, r0462, r0463, r0464
Notice: An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note: The individual characters of the identification number/serial number are available coded as ASCII characters.
Description: Displays the resolution of the absolute position for a linear absolute encoder.
Dependency: Refer to: p0422, p9514
Description: Displays the resolution of the absolute position for a linear absolute encoder.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p0422, p9514
Description: Displays the valid bits of the redundant coarse position value.
Dependency: Refer to: p9323, p9523
Description: Displays the valid bits of the redundant coarse position value.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: p9323, p9523
r0469 Absolute encoder linear measuring step / Enc lin meas step
ENC Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [nm] - [nm] - [nm]
r0469[0...2] Absolute encoder linear measuring step / Enc lin meas step
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [nm] - [nm] - [nm]
r0470 Redundant coarse position value valid bits / Valid bits
ENC Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0470[0...2] Redundant coarse position value valid bits / Valid bits
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -

Table of Contents