List Manual (LH2), 04/2014, A5E03263479A
735
2 Parameters
2.2 List of parameters
Note: Re index 0:
Displays the internal firmware version (e.g. 04402315).
This firmware version is the version of the memory card/device memory and not the CU firmware (r0018), however,
normally they have the same versions.
Re index 1:
Displays the external firmware version (e.g. 04040000 -> 4.4).
For automation systems with SINAMICS Integrated this is the runtime version of the automation system.
Re index 2:
Displays the internal firmware version of the parameter backup.
With this CU firmware version, the parameter backup was saved, which was used when powering up.
Description: Displays whether, for an activated drive object, all activated topology components are available or not (or whether
these can be addressed).
0: Drive object not ready for operation
1: Drive object ready for operation
Description: Displays the number of indices for r7853[0...n].
This corresponds to the number of DRIVE-CLiQ components that are in the target topology.
Dependency: Refer to: r7853
Note: The values are valid if all available Control Units adopt the "Initialization finished" state (r3988 = 800) following
power-up.
Description: Displays the component and whether this component is currently present.
High byte: Component number
Low byte: 0/1 (not available/available)
Dependency: Refer to: p7852
Note: The values are valid if all available Control Units adopt the "Initialization finished" state (r3988 = 800) following
power-up.
r7850[0...n] Drive object operational/not operational / DO ready for oper
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-32786 32767 -
p7852 Number of indices for r7853 / Qty indices r7853
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 200 1
r7853[0...n] Component available/not available / Comp present
CU_G130_DP,
CU_G130_PN,
CU_G150_DP,
CU_G150_PN
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: p7852 Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF hex -