SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
41
2 Parameters
2.2 List of parameters
Description: Sets the parameter filter to commission an infeed unit.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
Value: 0: Ready
1: Quick commissioning
2: Power unit commissioning
5: Technological application/units
29: Only Siemens int
30: Parameter reset
Note: The drive can only be powered up outside the drive commissioning (inverter enable). To realize this, this parameter
must be set to 0.
For p3900 not equal to 0, at the end of the quick commissioning, this parameter is automatically reset to 0.
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description: Sets the parameter filter to commission an encoder drive object.
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value: 0: Ready
4: Encoder commissioning
5: Technological application/units
29: Only Siemens int
30: Parameter reset
Note: Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description: Sets the parameter filter for commissioning a Terminal Board 30 (TB30).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value: 0: Ready
29: Only Siemens int
30: Parameter reset
Dependency: Refer to: p0970
Note: Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
p0010 Infeed commissioning parameter filter / INF comm par_filt
B_INF Can be changed: C2(1), T Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 30 1
p0010 Encoder DO commissioning parameter filter / EncDO com par_filt
ENC Can be changed: C2(1), T Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 30 0
p0010 TB30 commissioning parameter filter / TB30 comm.par_filt
TB30 Can be changed: C2(1), T Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 30 0