SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
713
2 Parameters
2.2 List of parameters
Description: Displays the measured offset of phase W as peak value.
The summed value of all power units is displayed in r0069[5].
Description: Displays the measured sum of the currents in phases U, V and W as instantaneous value.
The summed value of all power units is displayed in r0069[6].
Description: Displays the measured actual value of the DC link voltage.
The average value of all power units is displayed in r0070.
Description: Displays the actual voltage, phase U.
The average value of all power units is displayed in r0089[0].
Description: Displays the actual voltage, phase V.
The average value of all power units is displayed in r0089[1].
r7228[0...n] CO: Par_circuit phase current actual value phase W offset / I_phase W offset
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7229[0...n] CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7230[0...n] CO: Par_circuit DC link voltage actual value / Vdc_act
B_INF (Parallel),
VECTOR_G (Parallel)
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_2 Unit selection: p0505
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7231[0...n] CO: Par_circuit phase voltage actual value phase U / U_phase U act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r7232[0...n] CO: Par_circuit phase voltage actual value phase V / U_phase V act val
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Units group: 5_3 Unit selection: p0505
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]