2 Parameters
2.2 List of parameters
SINAMICS G130/G150
402 List Manual (LH2), 04/2014, A5E03263479A
Description: Displays the effective P gain of the current model controller.
Description: Displays the effective integral time of the current model controller.
Description: Displays the effective flux setpoint of the current model.
The value is referred to the rated motor flux.
Description: Displays the effective flux actual value of the current model.
The value is referred to the rated motor flux.
Description: Displays the I component of the current model controller.
r1631 Current model controller P gain effective / I_modctrlKpeff
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- - -
r1632 Current model controller integral time effective / I_mod_ctrl Tn eff
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r1633 Current model flux setpoint / I_mod flux setp
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r1634 Current model flux actual value / I_mod flux act val
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r1635 Current model controller I component / I_mod_ctrl I comp
VECTOR_G (n/M) Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6727
P-Group: Closed-loop control Units group: 6_2 Unit selection: p0505
Not for motor type: ASM, PEM, REL Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]