Fig. 3-95 2847 – TM54F parameter manager
- 2847 -
Function diagram
87654321
fp_2847_51_eng.vsd
DO: TM54F_MA, TM54F_SL
SINAMICSSI Extended Functions - TM54F parameter manager
Changing Safety parameters
SI password input
p10061
Resetting safety parameters
Disabling Safety functions
x
p10000 (12.00 ms)
06.03.13 V04.07.00
Safety parameter
p10000 p10099
can be reset to
factory settings via
p0970
Safety parameter
p10000 ... p10099
can be changed
SI password new
p10062
SI ackn password
p10063
Safety parameterization enable
y
Effective password
=
Password entry
=
SET
y = x
Safety parameters
p10000 p10099
are valid after
POWER ON
<1> The target checksum must be equal to the actual check sum.
p10005
SI ref CRC TM54F_SL
r10004
SI act CRC TM54F_SL
SI ref CRC TM54F_MA
p10005
SI act CRC TM54F_MA
r10004
p0010 95
Quit Safety commissioning mode
Checksum check
for
Safety parameters
& &
Safety Integrated commissioning
p0010 = 95
Commissioning mode active (p0010 = 95)
r10054.0
SI drv_obj assign_MA
p10010[0...5] = 0
SI drv_obj assign_SL
p10010[0..5] = 0
&
<1>
<1>
=
=