EasyManua.ls Logo

Siemens SINAMICS G150 - Page 1145

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
1145
3 Function diagrams
3.10 Safety Integrated Extended Functions
Fig. 3-102 2857 – TM54F assignment (F-DO 0 ... F-DO 3)
- 2857 -
Function diagram
87654321
DO: TM54F_MA, TM54F_SL
SINAMICS
23.03.12 V04.07.00
SI Extended Functions - TM54F assignment (F-DO 0 ... F-DO 3)
fp_2857_51_eng.vsd
p10000.00 (12.00 ms)
F-DO 0
[2853.8]
[2853.8]
[2853.8]
[2853.8]
F-DO 3
F-DO 2
F-DO 1
SI F-DO 0 S_src
p10042[0]
<1>
If one input is not connected to
a signal source, this input is set
to HIGH (default setting).
Exception:
If all outputs are not connected
to a signal source, the output
signal is 0.
&
&
&
&
SI F-DO 0 S_src
p10042[1]
SI F-DO 0 S_src
p10042[2]
SI F-DO 0 S_src
p10042[3]
SI F-DO 0 S_src
p10042[4]
SI F-DO 0 S_src
p10042[5]
1
4
3
2
5
6
SI F-DO 1 S_src
p10043[0]
SI F-DO 1 S_src
p10043[1]
SI F-DO 1 S_src
p10043[2]
SI F-DO 1 S_src
p10043[3]
SI F-DO 1 S_src
p10043[4]
SI F-DO 1 S_src
p10043[5]
1
4
3
2
5
6
1
4
3
2
5
6
SI F-DO 2 S_src
p10044[1]
SI F-DO 2 S_src
p10044[2]
SI F-DO 2 S_src
p10044[3]
SI F-DO 2 S_src
p10044[4]
SI F-DO 2 S_src
p10044[5]
SI F-DO 2 S_src
p10044[0]
1
4
3
2
5
6
SI F-DO 3 S_src
p10045[1]
SI F-DO 3 S_src
p10045[2]
SI F-DO 3 S_src
p10045[3]
SI F-DO 3 S_src
p10045[4]
SI F-DO 3 S_src
p10045[5]
SI F-DO 3 S_src
p10045[0]
<1>
<1>
<1>
<1>
[2855.8]
[2855.8]
[2855.8]
[2855.8]
3: Drive group 1 SS2 active
2: Drive group 1 SS1 active
1: Drive group 1 pulses suppressed
4: Drive group 1 SOS active
5: Drive group 1 SLS active
7: Drive group 1 safe state
0: No function
9: Drive group 1 internal event
8: Drive group 1 SOS selected
6: Drive group 1 SSM feedback signal active
[2855.8]
[2855.8]
[2855.8]
[2855.8]
[2856.8]
257: Drive group 2 pulses suppressed
[2855.8]
[2855.8]
[2855.8]
[2855.8]
[2855.8]
771: Drive group 4 SS2 active
770: Drive group 4 SS1 active
769: Drive group 4 pulses suppressed
772: Drive group 4 SOS active
773: Drive group 4 SLS active
775: Drive group 4 Safe state
777: Drive group 4 internal event
776: Drive group 4 SOS selected
774: Drive group 4 SSM feedback signal active
[2855.8]
[2855.8]
[2855.8]
[2855.8]
[2856.8]
10: Drive group 1 active SLS stage bit 0
11: Drive group 1 active SLS stage bit 1
12: Drive group 1 SDI positive active
[2855.8]
[2855.8]
[2855.8]
[2855.8]
[2856.8]
13: Drive group 1 SDI negative active
[2855.8]
271: Drive group 2 active SLP stage
780: Drive group 4 SDI positive active
781: Drive group 4 SDI negative active
[2855.8]
[2855.8]
778: Drive group 4 active SLS stage bit 0
778: Drive group 4 active SLS stage bit 1
[2855.8]
513: Drive group 3 pulses suppressed
[2855.8]
[2856.8]
527: Drive group 3 active SLP stage
782: Drive group 4 SLP active
[2855.8]
15: Drive group 1 active SLP stage
[2855.8]
14: Drive group 1 SLP aktiv
[2855.8]
783: Drive group 4 active SLP stage
[2855.8]

Table of Contents

Other manuals for Siemens SINAMICS G150