3 Function diagrams
3.17 Signals and monitoring functions
Fig. 3-155 8011 – Speed signals 2
- 8011 -
Function diagram
87654321
fp_8011_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
11.04.12 V04.07.00
Signals and monitoring functions - Speed signals 2
Ramp-up/ramp-down completed
r2199.5 [2537.3]
+
SET
(Q=1)
RESET
(Q=0)
Q
Q
n_act 2
0
p2154[C]
p0115[3] (4000.00 μs)p0115[3] (<3>)
r2169
n_act smooth signal
[8010.2]
0
1
n_hysteresis 3
0.00...300.00 [rpm]
p2150[D] (2.00)
<2>
n_act 0
r2197.3 [2534.3]
0
n_set for msg
r1170
p2151[C]
<5>
[3080.8]
n_thresh val 4
0.00...210.000 [rpm]
p2163[D] (90.00)
n_hysteresis 4
0.00...200.00 [rpm]
p2164[D] (2.00)
<2>
0
1
0
1
0
0
1
n_hysteresis 3
0.00...300.00 [rpm]
p2150[D] (2.00)
<2>
n_hysteresis 3
0.00...300.00 [rpm]
p2150[D] (2.00)
(0)
RFG active
p2148[C]
t_on n_act=n_set
0.0...10 000.0 [ms]
p2167[D] (200.0)
T0
1 = RESET
Priority
1 RESET
2 SET
[2537.3]
Speed setpoint actual value deviation in tolerance t_on
r2199.4
0T
t_del_off n_i=n_se
0.0...500.0 [ms]
p2166[D] (200.0)
Speed setpoint actual value deviation in tolerance t_off
r2197.7 [2534.3]
1
<4>
Torque control active
r1407.2
[6060.3]
Enable alarm A07903
p2149.0[D]
A07903 "Motor speed deviation"
0
0
1
A07903 is only signaled for p2149.0 = 1 and r2197.7 = 0.
n_thresh val 3
0.00...210000.00 [rpm]
p2161[D] (5.00)
n_set > 0
r2198.5 [2536.3]
|n_set| < p2161
r2198.4 [2536.3]
+
[5210.4]
n_set for msg
r1438
p2151[C]
<6>
<1>
<1> Applies only if the function module "extended
signals/monitoring functions" is active
(r0108.17 = 1).
<2> VECTOR: Calculated.
<3> VECTOR:
Depending on the drive unit (1000 or 1600 μs).
<4> Evaluation only for:
Pulse enable and operating enable (r0899.2)
or OFF1
or OFF3
or rotating measurements
or friction characteristic plot.
<5> Only for VECTOR.
<6> Only for SINAMICS S120 and SERVO.
<7> The value is displayed correctly only with
r0899.2 = 1 (Operation enabled).