Fig. 3-159 8016 – Thermal monitoring, motor
- 8016 -
Function diagram
87654321
fp_8016_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
28.01.14 V04.07.00
Signals and monitoring functions - Thermal monitoring, motor
Mot_temp_sens type
p0601[M]
Mot temp_sensor
p0600[M]
48 ms
r0035
Mot_temp
T0
&
&
Mod 2/KTY t_timer
p0606[M]
A07910
"Motor overtemperature"
F07011
"Motor overtemperature"
<1>
Fault response
I_max reduction
[6300.1], [6640.2]
Mot temp response
p0610[M]
p0610 = 1
Suppress fault
at p0610 = 0
[2548.2]
r2135.14
A07820 "Temperature sensor not connected"
A07015
"Motor temperature
sensor fault alarm"
A07016
"Motor temperature
sensor fault, fault"
-140 °C 250 °C
Sensor fault time
p0607[M]
<2>
0
1
Mod 1/2 threshold
p0605[M]
&
KTY sensor type
(threshold not applicable for PTC)
<4>
1
1
[2548.2]r2135.12
T0
<5>
KTY PTC
Sensor type
Mod 2/KTY A thresh
p0604[M]
0
1
<3>
M I N
Mot temp alarm 1
p0616[M]
<8>
1650
1
MAX
1
<1> For KTY, PT100, PT1000 and PTC, the value p0606 = 0 has a different meaning:
KTY, PT100, PT1000: 0 The output of the timer is always switched out (logical 0)
PTC: 0 Delay time = 0 s
<2> The switch-in delay p0607 = 0 suppresses fault F07016.
<3> For KTY, PT100, PT1000 and "No sensor", temperature as defined in the model.
<4> Applies only for VECTOR.
<5> p0606 does not work for alarms via p0616.
<6> p0601 = 5 can only be evaluated if r0192.15 = 1 and p0600 = 11; PT100 is calibrated via p0624.
<7> The assignment of temperature channels 1 4 depends on the hardware used.
<8> The relevant rated response temperature (°C) depends on the temperature sensor chosen by the motor manufacturer.
e.g. r4105 from TM31
[8017.8]
1
Mot Temperatur [°C]
(0)
p0603
[4704.8]
from Motor Modules
or CUA31
von Geber 3
[4704.8]
from encoder 1
[4704.8]
10 = Evaluation
across several
temperature
channels
SME12x
[9576.7]
0
1
2
3
11
10
from encoder 2
2 = KTY84
4 = Bimetal NC
contact alarm
with time step
for MM only
5 = PT100
<6>
11 = Evaluation
across several
temperature
channels BICO
Mot temperatur [°C]
(0)
p0608[0...3]
Mot temperatur [°C]
(0)
p0609[0...3]
20
21
0 = No sensor
3 = KTY84 & PTC,
for encoder only
1 = PTC alarm and
time
Mot Temp_sensortyp
Temp_sens type
p4603[E]
r4620[0] r4620[1] r4620[2] r4620[3]
p4600[E] p4601[E] p4602[E]
12
34
Temperature channel
Mot Temp_sensortyp
Temp sens type MDS
p4613[M]
r4620[0] r4620[1] r4620[2] r4620[3]
p4610[M] p4611[M] p4612[M]
12
34
Temperature channel
30 = Bimetal NC contact fault
12 = PTC alarm and time step
32 = Bimetal NC contact
alarm & time step
31 = Bimetal NC contact alarm
0 = No sensor
11 = PTC alarm
Configuration
10 = PTC fault
20 = KTY, PT100, PT1000
<7>
e.g. r4105 from TM120
e.g. r4105 from TM120
[8017.1]
only for KTY
[8017.8]
from mot temp module 1
[8017.8]