3 Function diagrams
3.20 Basic Infeed
Fig. 3-174 8726 – Status word, sequence control infeed
- 8726 -
Function diagram
87654321
fp_8726_54_eng.vsd
DO: B_INF
S120/S150/G130/G150
21.10.10 V04.07.00
Basic Infeed - Status word, sequence control infeed
[8732] From sequence control
[8732] From sequence control
[8732] From sequence control
[8732] From sequence control
[8732] From sequence control
[8750] From power unit
[8734.4] From line contactor control
p0115[3] (2000.00 μs)
r0899.0
r0899.1
r0899.2
r0899.4
r0899.6
r0899.11
r0899.12
r0899.9
r0899
ZSW sequence ctrl
<1> The drive object is ready to accept data.
<2> Only for S120 and G150.
Bit 9 = 1 --> Ready to exchange process data
11
12
13
14
15
Bit
No.
10
9
8
7
6
5
4
3
0
1
2
1 = Ready for operation
1 = Ready for switching on
Status word sequence control infeed
1 = Operation enabled
Reserved
1 = No OFF2 active
1 = Switching on inhibited
Reserved
Reserved
1 = Control requested
Reserved
1 = Pre-charging completed
1 = Line contactor closed
Reserved
Reserved
Reserved
Reserved
<1>
[8760.5]
<2>